Skip to main content
Loading…
This section is included in your selections.

(1) For any development activity or action requiring a project permit, the applicant shall submit a site development plan drawn to a standard engineering scale which includes:

(a) Boundary lines and dimensions of the subject property;

(b) Boundary lines and dimensions of the site;

(c) Topography at contour intervals of five feet unless the underlying project permit requires a lesser interval;

(d) Location, size, and type of any existing structures, cleared areas or other existing improvements;

(e) Location, size and type of all proposed structures and development activities requiring project permits and clearing on the site;

(f) Location, size and type of all critical aquifer recharge areas on the subject property;

(g) Location of all other critical areas regulated pursuant to chapters 30.62A, 30.62B and 30.65 SCC on and within 200 feet of the site; and

(h) Location of structure setbacks as required in chapter 30.62A SCC and chapter 30.23 SCC; and

(2) A hydrogeologic report as required pursuant to SCC 30.62C.140. (Added by Amended Ord. 06-061, Aug. 1, 2007, Eff date Oct. 1, 2007; Amended by Amended Ord. 15-034, Sept. 2, 2015, Eff date Nov. 1, 2015).