30.26.030 Number of spaces required.
(1) The required number of off-street parking spaces shall be as set forth in SCC Table 30.26.030(1) subject to provisions, where applicable, regarding:
(a) Effective alternatives to automobile access (SCC 30.26.040);
(c) Accessible routes of travel (SCC 30.26.065(7)).
(2) The abbreviations in the table have the following meanings:
(a) "GFA" means gross floor area;
(b) "GLA" means gross leasable area; and
(c) "SF" means square feet.
(3) Any off-street parking spaces that are devoted to electrical vehicle charging shall be counted toward the minimum number of parking spaces required.
(4) For off-street parking requirements in the Urban Center (UC) zone, see SCC 30.26.032.
USE |
Number of Spaces Required in R-9,600, R-8,400, R-7,200, WFB, T, MR, LDMR, GC, CB, NB, PCB, MHP, HI, LI, BP, and IP |
Number of Spaces Required in RD, RRT-10, R-5, RB, CRC, RFS, RI, F, F&R, A-10, SA-1, RC, RU, R-20,000, R-12,500 |
NOTES |
---|---|---|---|
No parking required |
1 per unit |
||
See SCC 30.26.035 |
See SCC 30.26.035 |
||
No parking required |
No parking required |
||
Air Terminal |
10 per 1,000 SF of waiting area |
10 per 1,000 SF of waiting area |
|
Stage 1 Utility |
See SCC 30.26.035 |
See SCC 30.26.035 |
|
All Others |
See SCC 30.26.035 |
See SCC 30.26.035 |
|
Amusement Facility, by type |
|||
Tennis courts, racquet or handball clubs, and similar commercial recreation |
10 per 1,000 SF assembly area plus 2 per court |
15 per 1,000 SF assembly area plus 2 per court |
|
Theaters and cinemas |
1 per 3 seats or 8 feet of bench |
1 per 4 seats or 8 feet of bench |
|
All other places without fixed seats including dance halls and skating rinks |
See SCC 30.26.035 |
See SCC 30.26.035 |
|
3 per 1,000 GFA |
4 per 1,000 GFA |
||
Art Gallery 41 |
2.5 per 1,000 GFA |
2.5 per 1,000 GFA |
|
See SCC 30.26.035 |
See SCC 30.26.035 |
||
Auto Repair, Major |
5 per 1,000 GFA |
5 per 1,000 GFA |
Service bays and work areas inside repair facilities do not count as parking spaces. |
Auto Repair, Minor |
4 per 1,000 GFA |
5 per 1,000 GFA |
Service bays and work areas inside repair facilities do not count as parking spaces. |
See SCC 30.26.035 |
See SCC 30.26.035 |
||
Auto Wrecking and Junkyard |
15 spaces for yards less than 10 acres in size; 25 spaces for yards 10 acres or larger |
15 spaces for yards less than 10 acres in size; 25 spaces for yards 10 acres or larger |
|
2 spaces |
2 spaces |
||
Bed and Breakfast Guesthouses and Inns |
2 plus 1 per guest room |
2 plus 1 per guest room |
|
1 per guest room |
1 per guest room |
||
Boat Launch, Commercial |
See SCC 30.22.130(31) |
See SCC 30.22.130(31) |
|
Boat Launch, Non-commercial |
See SCC 30.22.130(31) |
See SCC 30.22.130(31) |
|
2 per unit |
2 per unit |
||
1 per 4 seats or 8 feet of bench, or 25 per 1,000 sf of assembly room with no fixed seats |
1 per 4 seats or 8 feet of bench, or 25 per 1,000 sf of assembly room with no fixed seats |
||
See SCC 30.26.035 |
See SCC 30.26.035 |
||
See SCC 30.26.035 |
See SCC 30.26.035 |
||
See SCC 30.22.130(33) |
See SCC 30.22.130(33) |
||
See SCC 30.26.035 |
See SCC 30.26.035 |
||
See SCC 30.26.035 |
See SCC 30.26.035 |
||
See SCC 30.26.035 |
See SCC 30.26.035 |
||
Dams, Power Plants, & Associated Uses |
See SCC 30.26.035 |
See SCC 30.26.035 |
|
Day Care Center |
1 per employee plus load/unload space |
1 per employee plus load/unload space |
An off-street load and unload area equivalent to one space for each 10 children is also required. |
2 per 1,000 GFA |
2.5 per 1,000 GFA |
May also be determined by the department on a case-by-case basis per SCC 30.26.035 when the employee to SF GFA ratio for the proposed use is less than the typical requirement for this use in this zone. |
|
No Parking Requirement |
No Parking Requirement |
||
Note 1: Driveways between garage doors and roads, private roads, designated fire lanes or access aisles that are at least 19' long and 8.5' wide may be counted as one parking space and if at least 19' long and 17' wide may be counted as two parking spaces. Garages shall have a minimum interior length of 19'. |
|||
Cottage Housing |
2 spaces per dwelling unit plus guest parking at 1 space per 4 dwellings |
2 spaces per dwelling unit plus guest parking at 1 space per 4 dwellings |
|
Attached Single Family |
2 per dwelling; see note 1 |
2 per dwelling; see note 1 |
|
2 per dwelling; see note 1 |
2 per dwelling; see note 1 |
||
2 per dwelling; see note 1 |
2 per dwelling; see note 1 |
||
Multifamily |
2 per dwelling; see note 1 |
2 per dwelling; see note 1 |
|
Single Family |
2 per dwelling; see note 1 |
2 per dwelling; see note 1 |
|
2 per dwelling; see note 1 |
2 per dwelling; see note 1 |
Note 2: |
|
Single Family Detached Units (pursuant to chapter 30.41F SCC) |
2 spaces per dwelling unit plus guest parking at 1 space per 4 dwellings provided that 1 unrestricted guest parking spot per 2 dwellings for either (i) dwellings where no driveways are provided or (ii) dwellings that provide a driveway apron meeting the minimum dimension requirements for parking of only 1 car; see notes 1 & 2. |
2 spaces per dwelling plus guest parking at 1 space per 4 dwellings provided that 1 unrestricted guest parking spot per 2 dwellings for either (i) dwellings where no driveways are provided or (ii) dwellings that provide a driveway apron meeting the minimum dimension requirements for parking of only 1 car; see notes 1 & 2. |
An "unrestricted" guest parking spot is one provided either within the drive aisle parking or designated guest parking areas outside of individual units; garage parking spaces or parking spaces on driveway aprons of an individual unit are not "unrestricted" parking spaces. All applicable provisions of chapter 30.26 SCC shall be followed. |
Electric Vehicle Charging Station – Levels 1 to 3 |
No requirement |
No requirement |
Note: service bays and work areas inside repair facilities do not count as parking spaces. |
Battery Exchange Stations |
4 per 1,000 GFA |
5 per 1,000 GFA |
|
See SCC 30.26.035 |
See SCC 30.26.035 |
One space accommodating a vehicle and horse trailer for every two horses expected at equestrian or mini-equestrian center events. |
|
Excavation & Processing of Minerals |
See SCC 30.26.035 |
See SCC 30.26.035 |
|
Explosives, Storage |
See SCC 30.26.035 |
See SCC 30.26.035 |
|
See SCC 30.26.035 |
See SCC 30.26.035 |
||
See dwelling, single family requirements |
See dwelling, single family requirements |
An off-street load and unload area equivalent to one space is also required. |
|
1 per 1,000 GFA |
1 per 1,000 GFA |
||
Up to 400 SF |
2 per stand |
2 per stand |
|
401 to 5,000 SF |
3 per 1,000 GFA (3 minimum) |
3 per 1,000 GFA (3 minimum) |
|
See SCC 30.26.035 |
See SCC 30.26.035 |
||
See SCC 30.26.035 |
See SCC 30.26.035 |
||
3 per 1,000 GFA (3 minimum) |
3 per 1,000 GFA (3 minimum) |
||
See SCC 30.26.035 |
See SCC 30.26.035 |
||
See SCC 30.26.035 |
See SCC 30.26.035 |
||
No Parking Required |
No Parking Required |
||
Forestry Industry Storage & Maintenance Facility |
See SCC 30.26.035 |
See SCC 30.26.035 |
|
See SCC 30.26.035 |
See SCC 30.26.035 |
||
See SCC 30.26.035 |
See SCC 30.26.035 |
||
Garage, Detached Private |
No Parking Required |
No Parking Required |
|
Golf Course, Driving Range, Country Club |
See SCC 30.26.035 |
See SCC 30.26.035 |
|
Government Structures & Facilities |
See SCC 30.26.035 |
See SCC 30.26.035 |
|
See SCC 30.26.035 |
See SCC 30.26.035 |
||
1 per guest house |
1 per guest house |
||
Hazardous Waste Storage & Treatment Facilities, Offsite or Onsite |
See SCC 30.26.035 |
See SCC 30.26.035 |
|
Health and Social Service Facilities, Levels I through III |
See SCC 30.26.035 |
See SCC 30.26.035 |
|
See SCC 30.26.035 |
See SCC 30.26.035 |
||
See dwelling, single family requirements |
See dwelling, single family requirements |
||
1 per unit or guest room; see note |
1 per unit or guest room; see note |
Additional parking for restaurants, conference or convention facilities and other businesses, facilities, or uses associated with the motel or hotel is required in accordance with this table. |
|
See SCC 30.26.035 |
See SCC 30.26.035 |
||
No Additional Requirement |
No Additional Requirement |
||
No Additional Requirement |
No Additional Requirement |
||
No Additional Requirement |
No Additional Requirement |
||
2.5 per 1,000 GFA |
3 per 1,000 GFA |
Or see SCC 30.26.035 |
|
2.5 per 1,000 GFA |
3 per 1,000 GFA |
||
See SCC 30.26.035 |
See SCC 30.26.035 |
||
2 per 1,000 GFA |
2 per 1,000 GFA |
||
Lumberyard |
1 per 1,000 GLA |
1 per 1,000 GLA |
|
2 per 1,000 GFA |
2.5 per 1,000 GFA |
May also be determined by the department on a case-by-case basis per SCC 30.26.035 when the employee to SF GFA ratio for the proposed use is less than the typical requirement for this use in this zone. |
|
Manufacturing-All Other Forms Not Specifically Listed |
2 per 1,000 GFA |
2.5 per 1,000 GFA |
May also be determined by the department on a case-by-case basis per SCC 30.26.035 when the employee to SF GFA ratio for the proposed use is less than the typical requirement for this use in this zone. |
2 per 1,000 GFA |
2.5 per 1,000 GFA |
May also be determined by the department on a case-by-case basis per SCC 30.26.035 when the employee to SF GFA ratio for the proposed use is less than the typical requirement for this use in this zone. |
|
2 per 1,000 GFA |
2.5 per 1,000 GFA |
May also be determined by the department on a case-by-case basis per SCC 30.26.035 when the employee to SF GFA ratio for the proposed use is less than the typical requirement for this use in this zone. |
|
3 per 1,000 GFA |
4 per 1,000 GFA |
||
Massage Parlor |
3 per 1,000 GFA |
4 per 1,000 GFA |
|
See SCC 30.26.035 |
See SCC 30.26.035 |
||
1 per 4 seats or 8 feet of bench; see note |
1 per 4 seats or 8 feet of bench; see note |
One space accommodating a vehicle and horse trailer for every two horses expected at equestrian or mini-equestrian center events. |
|
2 per 75 storage units |
2 per 75 storage units |
||
See chapter 30.42ESCC. |
|||
See SCC 30.26.035 |
See SCC 30.26.035 |
See SCC 30.26.035 |
|
See residential dwelling requirements |
See residential dwelling requirements |
||
See SCC 30.26.035 |
See SCC 30.26.035 |
||
2.5 per 1,000 GFA |
3 per 1,000 GFA |
||
3 per 1,000 GLA |
4 per 1,000 GLA |
||
2.5 per 1,000 GFA |
3 per 1,000 GFA |
A minimum of 5 spaces required for all sites. Drive-up windows at financial institutions must have clear queuing space, not interfering with parking areas, for at least three vehicles per drive up window. |
|
Off-road vehicle use area, private |
See SCC 30.26.035 |
See SCC 30.26.035 |
|
See Parks and Recreation Element of the Comprehensive Plan |
See Parks and Recreation Element of the Comprehensive Plan |
Parking standards for parks varies based on the classification of the park and amenities identified in the Parks and Recreation Element. |
|
No Additional Requirement |
No Additional Requirement |
||
No Additional Requirement |
No Additional Requirement |
||
1 space |
1 space |
||
2.5 per 1,000 GFA |
3 per 1,000 GFA |
||
Public Events/Assemblies on Farmland |
See SCC 30.26.035 |
See SCC 30.26.035 |
|
Race Track |
See SCC 30.26.035 |
See SCC 30.26.035 |
|
See SCC 30.26.035 |
See SCC 30.26.035 |
||
1 per RV |
1 per RV |
||
See SCC 30.26.035 |
See SCC 30.26.035 |
||
See SCC 30.26.035 |
See SCC 30.26.035 |
||
Rendering of Fat, Tallow, or Lard |
See SCC 30.26.035 |
See SCC 30.26.035 |
|
See SCC 30.26.035 |
See SCC 30.26.035 |
||
6 per 1,000 GFA |
8 per 1,000 GFA |
Clear queuing space, not interfering with the parking areas, for at least five vehicles is required in front of any drive up window. |
|
3 per 1,000 GFA |
4 per 1,000 GFA |
||
See SCC 30.26.040(1). |
|||
1 per dwelling |
See SCC 30.26.040(2). |
||
Rural Industries |
See SCC 30.26.035 |
See SCC 30.26.035 |
|
See SCC 30.26.035 |
See SCC 30.26.035 |
||
Schools |
See SCC 30.26.035 |
See SCC 30.26.035 |
See SCC 30.26.035; Sufficient on-site space for safe loading and unloading of students from school buses and cars is also required. |
K-12 & Preschool |
|||
College |
|||
Other |
|||
3 per 1,000 GFA |
4 per 1,000 GFA |
||
See SCC 30.26.035 |
See SCC 30.26.035 |
||
No parking required |
No parking required |
||
No parking required |
No parking required |
||
2 per 1,000 GFA |
2.5 per 1,000 GFA |
May also be determined by the department on a case-by-case basis per SCC 30.26.035 when the employee to SF GFA ratio is less than the normal minimum requirement for the zone. |
|
1 per 4 seats or 8 feet of bench; see note |
1 per 4 seats or 8 feet of bench; see note |
One space accommodating a vehicle and horse trailer for every two horses expected at equestrian or mini-equestrian center events. |
|
See SCC 30.26.035 |
See SCC 30.26.035 |
||
1 per 1,000 GFA |
1 per 1,000 GFA |
||
No parking required |
No parking required |
||
No parking required |
No parking required |
||
2.5 per 1,000 GFA |
3 per 1,000 GFA |
||
Public |
1 per 10 swimmers, based on pool capacity as defined by the Washington State Department of Health. |
1 per 10 swimmers, based on pool capacity as defined by the Washington State Department of Health. |
|
Private |
See SCC 30.26.035 |
See SCC 30.26.035 |
|
2.5 per 1,000 GFA |
3 per 1,000 GFA |
||
1 per dwelling |
1 per dwelling |
||
1 per dwelling |
1 per dwelling |
||
See SCC 30.26.035 |
See SCC 30.26.035 |
||
1 per coach |
1 per coach |
||
See SCC 30.26.035 |
See SCC 30.26.035 |
||
See SCC 30.26.035 |
See SCC 30.26.035 |
||
Utility Facilities, Electromagnetic Transmission & Receiving Facility |
1 space |
1 space |
|
Utility Facilities, Transmission Wires, Pipes & Supports |
See SCC 30.26.035 |
See SCC 30.26.035 |
|
Utility Facilities-All Other Structures |
1 space |
1 space |
|
Vehicle and Equipment Sales and Rental |
1 per 1,000 GFA of sales office, plus |
1 per 1,000 GFA of sales office, plus |
|
2 per 1,000 GFA of service or repair space, plus |
2 per 1,000 GFA of service or repair space, plus |
||
1 per 4,000 SF of outdoor display area (or of showroom display area in the CB zone) |
1 per 4,000 SF of outdoor display area (or of showroom display area in the CRC zone) |
||
3 per 1,000 GFA |
4 per 1,000 GFA |
||
0.5 per 1,000 GFA |
0.5 per 1,000 GFA |
||
See SCC 30.26.035 |
See SCC 30.26.035 |
||
1 per 1,000 GFA |
1 per 1,000 GFA |
||
1 per site plus 1 per 1,000 GFA |
1 per site plus 1 per 1,000 GFA |
||
All other uses not otherwise mentioned |
See SCC 30.26.035 |
See SCC 30.26.035 |
(Added by Amended Ord. 02-064, Dec. 9, 2002, Eff date Feb. 1, 2003; Amended by Amended Ord. 04-010, Mar. 3, 2004, Eff date Mar. 15, 2004; Amended by Amended Ord. 05-040, July 6, 2005, Eff date Aug. 8, 2005; Amended by Amended Ord. 07-022, Apr. 23, 2007, Eff date June 4, 2007; Amended by Amended Ord. 08-101, Jan. 21, 2009, Eff date Apr. 21, 2009; Amended by Amended Ord. 10-102, Jan. 19, 2011, Eff date Jan. 30, 2011; Amended by Amended Ord. 16-073, Dec. 21, 2016, Eff date Feb. 19, 2017; Amended by Amended Ord. 16-013, Mar. 8, 2017, Eff date May 7, 2017; Amended by Amended Ord. 17-004, May 10, 2017, Eff date June 1, 2017; Amended by Ord. 18-011, Mar. 21, 2018, Eff date May 20, 2018; Amended by Ord. 19-021, June 19, 2019, Eff date July 4, 2019; Amended by Ord. 20-080, Dec. 16, 2020, Eff date Jan. 9, 2021; Amended by Amended Ord. 21-018, June 9, 2021, Eff date June 19, 2021; Amended by Amended Ord. 21-060, Oct. 6, 2021, Eff date Oct. 22, 2021).